JTW-ZCD-805感溫火災(zāi)探測(cè)器(別名,開(kāi)關(guān)量溫感探測(cè)器,以下簡(jiǎn)稱探測(cè)器)適用于商場(chǎng)、賓館、商店 、倉(cāng)庫(kù)、銀行、通信機(jī)房、等民用及工業(yè)場(chǎng)所的火災(zāi)預(yù)報(bào)警。探測(cè)器具有靈敏度高、穩(wěn)定可靠、耗電小、美觀耐用、使用方便等特點(diǎn)。
探測(cè)器可以接入以下設(shè)備:
可編程邏輯控制器,(PLC),
溫濕度傳感器,
智能開(kāi)關(guān)量信號(hào)采集顯示儀,
模擬數(shù)字采集器,
各類消防輸入模塊,
信號(hào)采集模塊,
安防報(bào)警主機(jī),監(jiān)控設(shè)備,
等可接收開(kāi)關(guān)量無(wú)源觸點(diǎn)信號(hào)的設(shè)備。
同時(shí),可通過(guò)煙感探測(cè)器來(lái)聯(lián)動(dòng)聲訊設(shè)備,風(fēng)機(jī)等。
探測(cè)器廣泛用于以下領(lǐng)域:
通信基站,環(huán)境監(jiān)控,
安防監(jiān)控,消防系統(tǒng),
智能小區(qū),樓宇對(duì)講,
儀器儀表,工控自動(dòng)化,
設(shè)備機(jī)房,變電站安全,
隧道安全,特殊區(qū)域,
空調(diào)電梯維護(hù),以太網(wǎng)遠(yuǎn)程監(jiān)控等。
一. 性能:
報(bào)警聲音: ≥80dB(或無(wú)聲)
供電電源: DC9V~DC28V
電 流: 靜態(tài)電流 ≤200uA
報(bào)警電流 ≤45mA
工作溫度: -10℃~+50℃
相對(duì)濕度: ≤95%RH(40℃±2℃)
輸出形式: 聲光報(bào)警/繼電器無(wú)源觸點(diǎn)(NO/NC可設(shè)置)輸出。
二. 功能:
自檢:按下檢測(cè)按鈕,探測(cè)器LED常亮,同時(shí)發(fā)出報(bào)警音響(注:自檢僅對(duì)于探測(cè)器本身內(nèi)部功能進(jìn)行檢測(cè),自檢時(shí)無(wú)繼電器信號(hào)輸出)。
工作:正常情況下,探測(cè)器大約每隔6秒指示燈會(huì)閃亮一下。探測(cè)器自動(dòng)檢測(cè)周圍環(huán)境中的溫度,并根據(jù)使用環(huán)境狀況進(jìn)行靈敏度自動(dòng)補(bǔ)償。當(dāng)溫度接近報(bào)警值,探測(cè)器加快對(duì)溫度濃度趨勢(shì)進(jìn)行智能運(yùn)算,同時(shí)報(bào)警指示燈開(kāi)始閃亮。若運(yùn)算結(jié)果達(dá)到或超過(guò)報(bào)警值,探測(cè)器開(kāi)始聲光報(bào)警,并啟動(dòng)繼電器輸出。當(dāng)周圍環(huán)境的溫度降低到報(bào)警值以下時(shí),探測(cè)器自動(dòng)恢復(fù)正常工作狀態(tài)。
輸出:無(wú)源觸點(diǎn)輸出;觸點(diǎn)容量24V/1A,可通過(guò)探測(cè)器內(nèi)部的跳線,設(shè)置為常開(kāi)或常閉觸點(diǎn)輸出。出廠時(shí)跳線默認(rèn)設(shè)置觸點(diǎn)為常閉。
一. 性能參數(shù)
中英對(duì)照信息 | 開(kāi)關(guān)量溫感 | Heat Detector with relay output |
型號(hào) | JTW-ZCD-805 | N.O:WT145 |
供電電源 | DC9V~DC28V | Operating Voltage Range: 9 to 28VDC Volts Non-polarized |
靜態(tài)電流 | 靜態(tài)電流 ≤200uA | Standby Current: ≤200μA@ 24 VDC |
報(bào)警電流 | ≤35mA | MaximumAlarm Current (LED on: ) ≤35mA@ 24 VDC |
報(bào)警溫度 | 定溫報(bào)警 : 57.2℃差溫報(bào)警 : 8.3℃/分鐘 | Fixed Temperature Rating135°F (57°C) |
尺寸 | 103x55mm | size 103x55 mm |
性能參數(shù):
報(bào)警聲音: ≥85dB/3米
供電電源: DC 9V~DC28V
定溫報(bào)警 : 58℃
差溫報(bào)警 : 8.3℃/分鐘
電 流 : 靜態(tài)電流 ≤200uA
報(bào)警電流 ≤50mA
工作溫度: -10℃~+50℃
相對(duì)濕度: ≤95%RH(40℃±2℃)
輸出形式: 繼電器無(wú)源觸點(diǎn)輸出
觸點(diǎn)容量2A@DC24V
二.安裝:
在天花板上相距60mm的位置上打兩個(gè)直徑5mm的安裝孔,用漲塞和螺釘固定探測(cè)器底座在天花板上。
注意:該產(chǎn)品不適宜在以下場(chǎng)所使用:
- 正常情況下溫度比較高或者變化大的的場(chǎng)所
英文版:
1. GENERAL DESCRIPTION
The detectors are photo-electronic detector uses a state of-the-artoptical sensing chamber. This detector is designed to provide open area protection and to be used with most security alarm control panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
Heat detector and smoke & heat detector combine a photo electronic sensing chamber and a temperature heat detector.
2. SPECIFICATIONS
Operating Voltage Range: 9 to 28 VDC Volts Non-polarized
Standby Current: ≤200μA
Maximum Alarm Current (LED on): ≤45mA
Alarm Relay Contact Ratings: 2A@ 24V DC
Operating Humidity Range: ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing
Operating Temperature Range: -10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity: 1.06±.26%FT
Temperature Alarm Sensitivity: 57°C (135°F) A1R (only for with heat sensor)
Height: 55 mm installed in Base
Diameter: 103 mm
WARNING
TO PREVENT DETECTOR CONTAMINATION AND SUBSEQUENT WARRANTY CANCELLATION, THE SMOKE
DETECTOR MUST REMAIN COVERED UNTIL THE AREA IS CLEAN AND DUST FREE.
3. INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
INSTALL THE DETECTOR BASE
1. Open area smoke or heat detectors are intended for mounting on a ceiling or a wall in accordance with the fire standard in your country.
2. Attach mounting base to ceiling or wall. The base of the detector can be mounted directly onto an electrical junction box such as an octagonal (75mm, 90mm or100mm), a round (75mm), or a square (100mm) box without using any type of mechanical adapter.
3. Position all wires flat against terminals, and fasten the wires on the terminals, See Figure 1.
4. Terminals function description:
Terminal 1: Relay Output -COM
Terminal 2: Relay Output – NO/NC (default NO)
Terminal 3: DC Power –
Terminal 4: DC Power +